Posted  by  admin

W Plot Diagram

  1. A scatter plot (also called a scatterplot, scatter graph, scatter chart, scattergram, or scatter diagram) is a type of plot or mathematical diagram using Cartesian coordinates to display values for typically two variables for a set of data. If the points are coded (color/shape/size), one additional variable can be displayed. The data are displayed as a collection of points, each having the.
  2. Movie Plot Diagram: Enchanted Climax: Evil Queen Narissa Queen Narissa appears at ball in disguise tricks Giselle into eating poison apple Giselle is unconscious; Robert kisses her and revives her Queen Narissa was caught, but changes to vicious beast and kidnaps Robert Falling.
  3. Conflict Plot Diagram Title Themes Marigolds are known as 'The herb of sun' which stands for passion and creativity. To recognize and understand the rising action of Eugenia W. Collier's short story Marigolds, the reader also needs to identify other plot elements and make. In the story Lizabeth is trying to find herself, and in the process she.
  1. W Plot Diagram Worksheet
  2. W Plot Diagram Pdf
  • Control Systems Tutorial
Pdf
  • Control Systems Useful Resources
  • Selected Reading

The Bode plot or the Bode diagram consists of two plots −

To enable screen reader support, press Ctrl+Alt+Z To learn about keyboard shortcuts, press Ctrl+slash.

  • Magnitude plot
  • Phase plot

In both the plots, x-axis represents angular frequency (logarithmic scale). Whereas, yaxis represents the magnitude (linear scale) of open loop transfer function in the magnitude plot and the phase angle (linear scale) of the open loop transfer function in the phase plot.

The magnitude of the open loop transfer function in dB is -

$$M=20: log G(jomega)H(jomega) $$

The phase angle of the open loop transfer function in degrees is -

$$phi=angle G(jomega)H(jomega)$$

Note − The base of logarithm is 10.

Basic of Bode Plots

The following table shows the slope, magnitude and the phase angle values of the terms present in the open loop transfer function. This data is useful while drawing the Bode plots.

Type of termG(jω)H(jω)Slope(dB/dec)Magnitude (dB)Phase angle(degrees)

Constant

$K$

$0$

$20 log K$

$0$

Zero at origin

$jomega$

$20$

$20 log omega$

$90$

‘n’ zeros at origin

$(jomega)^n$

$20: n$

$20: n log omega$

$90: n$

Pole at origin

$frac{1}{jomega}$

$-20$

$-20 log omega$

$-90 : or : 270$

‘n’ poles at origin

$frac{1}{(jomega)^n}$

$-20: n$

$-20 : n log omega$

$-90 : n : or : 270 : n$

Simple zero

$1+jomega r$

$20$

$0: for: omega < frac{1}{r}$

$20: log omega r: for : omega > frac{1}{r}$

$0 : for : omega < frac{1}{r}$

$90 : for : omega > frac{1}{r}$

Simple pole

$frac{1}{1+jomega r}$

$-20$

$0: for: omega < frac{1}{r}$

$-20: log omega r: for: omega > frac{1}{r}$

$0 : for : omega < frac{1}{r}$

$-90: or : 270 : for: omega > frac{1}{r}$

Second order derivative term

$omega_n^2left ( 1-frac{omega^2}{omega_n^2}+frac{2jdeltaomega}{omega_n} right )$

$40$

$40: log: omega_n: for : omega < omega_n$

$20: log:(2deltaomega_n^2): for : omega=omega_n$

$40 : log : omega:for :omega > omega_n$

$0 : for : omega < omega_n$

$90 : for : omega = omega_n$

$180 : for : omega > omega_n$

Second order integral term

$frac{1}{omega_n^2left ( 1-frac{omega^2}{omega_n^2}+frac{2jdeltaomega}{omega_n} right )}$

$-40$

$-40: log: omega_n: for : omega < omega_n$

$-20: log:(2deltaomega_n^2): for : omega=omega_n$

$-40 : log : omega:for :omega > omega_n$

$-0 : for : omega < omega_n$

$-90 : for : omega = omega_n$

$-180 : for : omega > omega_n$

Consider the open loop transfer function $G(s)H(s) = K$.

Magnitude $M = 20: log K$ dB

Phase angle $phi = 0$ degrees

W Plot Diagram Worksheet

If $K = 1$, then magnitude is 0 dB.

If $K > 1$, then magnitude will be positive.

If $K < 1$, then magnitude will be negative.

The following figure shows the corresponding Bode plot.

The magnitude plot is a horizontal line, which is independent of frequency. The 0 dB line itself is the magnitude plot when the value of K is one. For the positive values of K, the horizontal line will shift $20 :log K$ dB above the 0 dB line. For the negative values of K, the horizontal line will shift $20: log K$ dB below the 0 dB line. The Zero degrees line itself is the phase plot for all the positive values of K.

Consider the open loop transfer function $G(s)H(s) = s$.

Magnitude $M = 20 log omega$ dB

Phase angle $phi = 90^0$

At $omega = 0.1$ rad/sec, the magnitude is -20 dB.

At $omega = 1$ rad/sec, the magnitude is 0 dB.

At $omega = 10$ rad/sec, the magnitude is 20 dB.

W Plot Diagram Pdf

The following figure shows the corresponding Bode plot.

The magnitude plot is a line, which is having a slope of 20 dB/dec. This line started at $omega = 0.1$ rad/sec having a magnitude of -20 dB and it continues on the same slope. It is touching 0 dB line at $omega = 1$ rad/sec. In this case, the phase plot is 900 line.

Consider the open loop transfer function $G(s)H(s) = 1 + stau$.

Magnitude $M = 20: log sqrt{1 + omega^2tau^2}$ dB

Phase angle $phi = tan^{-1}omegatau$ degrees

For $ω < frac{1}{tau}$ , the magnitude is 0 dB and phase angle is 0 degrees.

For $omega > frac{1}{tau}$ , the magnitude is $20: log omegatau$ dB and phase angle is 900.

The following figure shows the corresponding Bode plot.

The magnitude plot is having magnitude of 0 dB upto $omega=frac{1}{tau}$ rad/sec. From $omega = frac{1}{tau}$ rad/sec, it is having a slope of 20 dB/dec. In this case, the phase plot is having phase angle of 0 degrees up to $omega = frac{1}{tau}$ rad/sec and from here, it is having phase angle of 900. This Bode plot is called the asymptotic Bode plot.

As the magnitude and the phase plots are represented with straight lines, the Exact Bode plots resemble the asymptotic Bode plots. The only difference is that the Exact Bode plots will have simple curves instead of straight lines.

Similarly, you can draw the Bode plots for other terms of the open loop transfer function which are given in the table.